Finally, back to this. I have setup 24v PSUs to inject power at the 1st and 3rd light as I has it last year and data/ ground coming from the Kulp and ...
I guess so. I purchased lights and PSUs from BST here back in 2023 and have used them all together since. I have started to incorporate pixels into my...
Sanity Check complete and it is def a power supply issue. I reconnected the PX1 to pc and old PS and everything worked. I then moved That setup and c...
I dug out the old Px1 this morning and sure enough it was wire as you suggested , v- and data from the controller and v+ from the meanwell, with groun...
Not sure I am smart enough to know what that means lol. I have a 3 wire pigtail connected to the kulp and the flood connected with the matching pigtai...
These are 3 wire floods not 4 wire. I am checking voltage from the + and - pins of the pigtail coming directly off the board and then also attaching t...
Getting 12.1 at the pigtail off the controller and rhe same coming out of the first flood. Also confirmed inout selector switch is set to 115. I wil...
These are 10w Ray wu style smart floods. The last 2 years I have run them off of Renard p1x and 2 125w meanwell powersupplys ( 2nd onw power i injwcte...
Test button from the Kulp provides the same results
When running test from FPP interface the light/lights connected to the port react in the behavior described. If I Cycle RGB I get BRIGHT RED, faint gr...
Thanks. With data only flowing one way I guess using 2 channels for the gutters would be the way to go. I have plans for power injection, based on cou...