rokkett
rokkett
@rokkett
Reputable Member
Joined: Oct 1, 2009
Topics: 29 / Replies: 412
Reply
RE: Dimming issues on a Ren 16SS

While both are serial communication protocols, RS-232 and RS-485 are electrically different. RS-232 is strictly voltage based with a shared ground an...

16 years ago
Forum
Reply
RE: Vixen FIle Format?

Fantastic! That makes sense now, so the eventdata matrix will be the number of channels * the number of event periods. Decode_base64 the entire arra...

16 years ago
Forum
Reply
RE: Dimming issues on a Ren 16SS

Is your USB to serial RS-232 or RS485? If it is 485, make sure the JP1 jumper is removed. If is 232, then make sure it is jumpered. Did you use the...

16 years ago
Forum
Topic
Forum
Replies: 22
Views: 21926
Reply
RE: Program Not Repeating

I agree, it is a hassle, but the computer scientist in me really, really wants it work. So I will keep playing until I figure it out.... (Did I say ...

16 years ago
Forum
Reply
RE: DC DC Power supply question - shared/common ground allowed?...

Pictures... Power Supplies velcro to door. Power cables fastened to make them hinge, rather than be loose in the enclosure. The closed enclosure wi...

16 years ago
Reply
RE: Program Not Repeating

How complicated is your background sequence? I have found that they can't be too complicated or they seem to lock up and not exit. Does yours contin...

16 years ago
Forum
Reply
RE: DC DC Power supply question - shared/common ground allowed?...

Ok, this actually works. Been testing this morning with a mighty-mini and a super strip and I am not having any issues. The correct voltages are de...

16 years ago
Reply
RE: Vixen gives error message when running a program with multiple sequences

With pull down menus, yes, you can only select times on the half hours. But you can type any minutes you want in the data entry box. Just click your...

16 years ago
Forum
Reply
RE: Vixen gives error message when running a program with multiple sequences

That is a common issue. And you are correct - Vixen only uses the start and end times to decide if the program should start, it will not stop a progr...

16 years ago
Forum
Reply
RE: Down and out...

I finally worked out all of my issues with my DC controllers and my mighty-mini floods. After several fits of just wanting to chuck the mighty-minis ...

16 years ago
Forum
Reply
RE: Easy? background script - help needed pls!

This technique fixed that problem for me. Make sure the program is set up so each sequence uses its own plugin configuration. Do not use the first t...

16 years ago
Reply
RE: DB-9M pinning for RS-485

Great feeling when it all comes together! Congrats... 🙂

16 years ago
Forum
Reply
RE: Vixen gives error message when running a program with multiple sequences

Try this: Create a sequence (not program) that is one or two seconds long, but has no plugins associated with it. In the program setup, select the o...

16 years ago
Forum