Hi All, Thanks to David, I got my system up and running. With his suggestions: 1. Use Output 2 for the Renard boards and the Pin config 1 to 5, 2 to ...
Here is my e131 setup, I have the first 2 universes for the Falcon and I left the 3rd alone. When I run a show the only items that work are the RGB-LE...
Mike, in my previous post I have my vixen setup. I have the falcon universes 1 and 2 then the rewards are 3rd. Sent from my iPhone using Tapatalk
Jumpers are as you indicated, my universes, first two are for the rgb/led lights and that is it. Sent from my iPhone using Tapatalk
Thanks Guys, So now I have the Renard side, like in post 5, and on the Falcon side, first RJ45 output is set correctly (according to the manual and it...
Thanks for the image! One final Q, doe I use a crossover schema or the RS485 to Renard schema?
Wait, I was under the impression that the cable from the Falcon to the first Renard was a standard ethernet. - Crossover cable! I will look into that...
Local newspapers and tvSent from my iPhone using Tapatalk
Hi All, A little late, however under the same heading. I have a Renard 24ss and in my troubleshooting regarding power, it has led me to suspecting t...
Thanks for the replies,Matt and Brian! Once I added the remaining output channels the units all worked! Also, I am running rs-232. Sent from my iPho...
MikelMD wrote:HI Team, So I have a very peculiar issue and I cannot figure the issue. I am running Vixen 3.2xx and here is the physical setup: Using...
How did you verify that the RJ45 jacks on the controller was bad? Was it simply b/c the data was not coming in - no lights were on?