ok i double checked. you were right it is about 2.5v on pin 2. here is a break down of the first three PIC sockets without the PICS installed. U10,...
yes 5v on pin 2
Well, I got all new PICs and a new oscillator. Replaced the new oscillator and flashed the new PICs. with the diag chip installed i still get no li...
ok just down loaded the diag with the internal oscillator and flashed a pic with it. diag lights worked on the chip 2 and 5 blinking (heartbeat and p...
Ok i used a multimeter and tested the bad board and found the following Pin 1 on PIX slots 5.01v point A on oscillator 5.00v point B on oscillator 5...
yes when i moved the pics back to the good board they still worked. and yes, the borken pic was in a board that i leave mounted on the side of the h...
good idea on all points. i will test. To answer the eariler asked question. Yes i did replace all the pics from a working board.
i can. altought i have no idea what to check or what the values should be. From the troubleshooting docs it seams it may be the oscillator. How c...
anyone who has these can you give a first hand experence between the 3 types? i like the short M5's but how do they look?
are power cables included?
anyone buy these yet? are they sturdy... looks like just a stiff wire with some fake branches off of them. would they support 4 100ct strings? ...
very nice.
I have decided to not accept the offers again. I think it would be really cool to walk outside and hand a family watching the show a gift certificate...